© 2020, JAPAN CASH MACHINE CO., LTD.
2 - 4
Section 2
UBA™ Pro Series Universal Banknote Acceptor
Installation
DIP Switch Configurations
Denomination Acceptance Settings
(DIP Switches at the front)
Table 2-1 lists the default Front DIP Switches con-
figurations for the acceptable denominations.
SW1 and SW2 Configurations
The UBA Pro CPU Circuit Board contains two (2)
DIP Switches that are located adjacent to one
another. The interface and the Recycler option can
be configured by these Switches (Figure 2-11).
Interface Settings (Sub Board 1)
The SW1 switch equipped on the Sub Board 1 is to
set an interface RS232C or Photo-Coupler Isola-
Interface and Recycler Settings (Sub
Board 2)
The SW1 switch equipped on the Sub Board 2 is to
set an interface RS232C, Photo-Coupler Isolation,
I-TTL2 or ccTalk (Table 2-3).
Table 2-1
Denomination Acceptance Settings
Switch No.
Switch ON/OFF
Description
1
ON
VEND 1 INHIBIT
OFF
VEND 1 ACCEPT
2
ON
VEND 2 INHIBIT
OFF
VEND 2 ACCEPT
3
ON
VEND 3 INHIBIT
OFF
VEND 3 ACCEPT
4
ON
VEND 4 INHIBIT
OFF
VEND 4 ACCEPT
5
ON
VEND 5 INHIBIT
OFF
VEND 5 ACCEPT
6
ON
VEND 6 INHIBIT
OFF
VEND 6 ACCEPT
7
ON
VEND 7 INHIBIT
OFF
VEND 7 ACCEPT
8
OFF
*
*. Not Applicable (N/A). Never Switched to ON.
OFF (Fixed)
NOTE: Front DIP Switch settings may vary
based on Software. Refer to each Country
’s
“
Software Information Sheet” for making the
proper switch settings.
ON
OFF
NOTE: Refer to the UBA Pro RT/RQ Series
Banknote Recycler Operation and
Maintenance Manual for the Recycler
options.
Figure 2-11
SW1 and SW2 Switches
SW1
SW2
Bottom View
Table 2-2
Sub Board 1 Interface Settings
Settings
Description
SW1
Photo-Coupler Isolation
RS232C
-
USB, TTL
SW2
Not available
-
Table 2-3
Sub Board 2 Interface Settings
Settings
Description
SW1
Photo-Coupler Isolation
I-TTL2
RS232C
cc-Talk
-
USB, TTL
(Except for I-TTL2)
SW2
To use a UBA Pro Unit
without a Recycler Unit(s)
*
*. Refer to the UBA Pro RT/RQ Series Operation and Maintenance Manual for using
the Recycler Unit(s).
NOTE: For the interface USB and TTL, no
need to configure the SW1 switch.
SW 1
SW 2
Front
Back
NOTE: For the interface USB and TTL
(except for I-TTL2), no need to configure the
SW1 switch.
SW 1
SW 2
Front
Back
Summary of Contents for UBA Pro Series
Page 8: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD v i THIS PAGE INTENTIONALLY LEFT BLANK...
Page 14: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i i THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i v THIS PAGE INTENTIONALLY LEFT BLANK...