________________________________________________________________________________________________________________________________________________________________
CN3600 Setup & Operation Manual Revision : 6/2020
7
2.4 CONNECTING TO ELECTRICAL SUPPLY
Connect power to machine according to electrical diagrams supplied (See back of Manual)
ENSURE CONNECTION IS ONLY DONE BY QUALIFIED ELECTRICAL PERSONNEL
DESCRIPTION
STANDARD
Supply voltage (Volts)
415
415
Supply Current (Amps)
26
26
3 phase, Earth (4 wire)
Supply Frequency (Hz)
50
60
The supply cable for this machine is to be of a size to
carry a load of 26 amp. The voltage required is
415 volt 3 phase. Other voltages can be supplied by a
transformer if required.
A supply connection (Fig. 2.4) is provided on the
terminal strip in the main cabinet. The terminals can be
located by looking for the larger terminals at the right
hand end of the terminal strip. These terminals are the
only spare terminals.
Fig. 2.4 Electrical Supply Connection
All wires should be checked for loose connections due to transport vibration.