________________________________________________________________________________________________________________________________________________________________
CN3600 Setup & Operation Manual Revision : 6/2020
53
Part
Method
No. of
Places
Lubricant
Check/Adjust
PNEUMATIC SYSTEM
Air Service Unit
1
Shell Morlina 32
Add oil when necessary as per manual.
Solonoid valves, seals & fittings
Apply soap and water solution with a
brush and check for air leaks and replace
where necessary.
NOTE:
Do not pump excessive grease into bearings
– 1 shot is sufficient
5.4 Yearly Maintenance
Every 12 months change battery in Servo Controller No:HCSFS 52
See date of commencement/anniversary date on label above Controller
–
Change battery on this date every year:
We strongly recommend this be done by the
local Mitsubishi Service Agent
NOTE: Failure to change battery can result in PLC losing programme