ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
Troubleshooting Page 7-11
Revised 10/14
V6
Power
Module,
cont.
Fuses
The
fuses
of
the
POWER
Module
are
located
underneath
a
protective
cover.
The
cover
should
only
be
removed
after
the
ASU
is
switched
Off
and
disconnected
from
the
main
power
supply.
After
checking
or
replacing
fuses,
the
cover
must
be
re-installed.
Heater
and
motor
driver
circuits
are
fused
on
both
legs
with
a
10A
fuse.
The
output
for
the
DC
power
supply
has
a
6.3
A
fuse.
Always
replace
fuses
with
the
same
type
of
fuse.
Voltage
Configuration
Connector
The
appropriate
voltage
configuration
plug
must
be
installed
for
the
machine
to
operate
properly.
Two
different
connectors
(plugs)
are
available:
PN
115725
-
240V
three
phase,
Delta
(violet)
PN
115726
-
400V
three
phase,
Wye
(yellow)