ITW Dynatec
Programming Page 5-11
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
Revised 1/16
Pump Control Screen/ Linear Line Speed
To go to this screen, press the Pump 2 field on the Pump Overview screen (to go to the Pump 1,
etc. Control screen, press the corresponding field). Then press the Settings button, select Linear
Line Speed in the Current Pump Mode menu on the Extended Pump Mode Settings screen and
then press the BACK button.
The Pump Control Linear Line Speed screen allows you to program the Auto Mode Settings
(Setpoint minimum/maximum RPM at 0–10VDC external signal control) and Manual Mode
Settings (Manual Setpoint RPM).
Pump 2 Example:
Item Description
1
Pump #2 is the selected pump. All the settings and speeds displayed on this screen
correspond to Pump #2.
2
Auto Mode Settings
Setpoint
The minimum and maximum setpoint values of the pump are displayed. The programmable
range is 0 to 90 rpm.
By pressing the input field you can edit the RPM values.
3
Manual Mode Settings
Manual Setpoint
The manual setpoint value of the pump is displayed.
By pressing the input field you can edit the value.
4
Press the arrow icon to go to the previous pump screen (ie, Pump 1, etc.).
5
1
8
6
2
3
7
9
10
11
4
Summary of Contents for DYNAMELT D15 Series
Page 3: ......
Page 4: ......
Page 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Page 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...