Page 7-20 Troubleshooting
Revised 10/14
ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
Problem
Possible Cause
Hopper Heater Open
1. Disconnection in hopper
heater circuit.
2. Disconnection between
Power Module and the
Temperature Module.
3. The ASU circuit breaker
(on the front panel) is
inoperative.
4. Open hopper heater
element.
(Optional) Drop-in Grid 1. Setpoints have been
Overtemp
programmed without
enough deviation.
2. Grid sensor inoperative.
3. Grid control solid state
relay inoperative.
AUX Power PCB
Heater
Sensor
Solution
1. Inspect hopper heater wiring for
proper connections.
2. Verify that all connections are
properly made between the Power
and Temperature Modules.
3.Visually and electrically inspect for a
short circuit to ground in the hopper
heater circuit. This will be limited to
between the hopper triac on the Power
Module and the hopper heater.
4. Remove both lead wires from
hopper heater plate. Use an ohm-
meter to measure resistance across
the plate. Infinitely high resistance
values indicate an open heating element
and heater plate which must be
replaced.
1. Re-program setpoints, allowing a
larger deviation between the high
and low limits.
2. Examine grid sensor assembly
for intermittent break in sensor lead.
Remove sensor bulb from grid. Replace
grid sensor if resistance does not
comply with resistance table.
3. Use a clamp-on ammeter to monitor
current on AUX Power PCB. If grid
zone is switched OFF, the current will
read 0 amps. If current still flows, re-
place shorted solid state relay.
Summary of Contents for DYNAMELT D15 Series
Page 3: ......
Page 4: ......
Page 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Page 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...