Controller Setup Page 4-9
Revised 10/14
Default Settings of the DynaControl V6 LCD Controller
Language: English
Setting for Customer Access Code: “1111”.
Standby temperature for all zones: 66
C (150
F) lower than programmed setpoints.
Hi/ lo limit deviation for all temperature zones: + 20
C (36
F).
Temperature zone offset: 0
C (0
F).
Setpoint limitation: 218
C (425
F).
Automatic sleep mode: Off.
Sequential heat-up: Off.
Power-On motor Stop: No.
Power-On heater start: Yes.
Global setpoints: No.
Minimum pump speed: 0 RPM).
Maximum pump speed: 90 RPM.
The ITW Dynatec factory default settings may be re-loaded in the controller per the instructions
given in Chapter 5: Zone Configuration (P1 parameter).