Page 3-6 Installation
Revised 10/14
ITW
Dynatec
D15/D25/D45
V6
DCL
ASU
Manual
#20-63
Terminal
Circuit
Location
‐ ‐
Input Power from Main Power 240VAC
See terminal block, L1, L2, L3
PE
Ground
See terminal block, PE
‐ ‐
Input Power from Main Power, 380VAC
See terminal block, L1, L2, L3
N
Neutral, 380VAC
See terminal block, N
PE
Ground
See terminal, PE
RELAY
Terminal Block, see R1 R2
OUTPUT 1
RELAY
Terminal Block, see A1 A2
OUTPUT 2
RELAY
Optional
OUTPUT 3
ST.BY
IN
-C.
Ready
Output
Signal
(contact
closes
when
ready)
Alarm
Output
Signal
(contact
opens
when
alarm)
Hopper
Low
Level
Signal
(contact
closes
when
glue
level
is
low)
IN2
IN3
IN4
PU.ST.
Standby Input
Recipe
Selection
1
Recipe
Selection
2
Reserved
External Pump Start/Stop
(activate to start pump)
Common for Inputs
LINE
COM
G+I or L+I
Line
Speed
Tracking
Voltage
(0
‐
10V)
Line
Speed
Tracking
Signal
with
Signal
Isolator
(option)
Optional.
Install
at
the
left
of
the
Base
Module.
Refer
to
schematic
for
details.
4. At installation, the customer must make the following terminal connections into the ASU’s
main power (ON/OFF) switch and modules. The modules do not need to be removed from the ASU
in order to make connections.
Refer to the detailed layout drawings of the components in Ch. 7 and/or the schematics in Ch. 11, if
needed.
Required connections for 380/400VAC, 3 phase, WYE ASU:
Required connections for 240VAC, 3 PH Delta ASU:
Non
‐
essential connections; connect if feature is installed:
V6 BASE Module, bottom side:
V6 BASE Module, bottom side:
Summary of Contents for DYNAMELT D15 Series
Page 3: ......
Page 4: ......
Page 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Page 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...