Page 6-4 Maintenance
Revised 10/14
ITW
Dynatec
D15/D25/D45
V6
DCL
ASU
Manual
#20-63
Pump Shaft Leak
There is a cutout in the base plate, directly below the pump
shaft, which will allow adhesive from a leaking pump to exit
the ASU. Inspect the area under the base plate cutout every
month for adhesive.
A leaking pump shaft indicates a worn pump seal. See
instructions in Chapter 8 for replacement of this seal.
Summary of Preventive Maintenance Schedule
Monthly
(or as experience dictates)
Inspect output filter basket.
Replace as required.
Check for leaking adhesive under the base plate, caused by a worn pump seal.
Replace as required.
Every Three Months
(or as experience dictates)
Check all hose fittings for tightness.
Check all fasteners for tightness.
Inspect primary filter.
Clean or replace as required.
Gear Pump
Seal Assembly
Summary of Contents for DYNAMELT D15 Series
Page 3: ......
Page 4: ......
Page 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Page 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...