ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
LCD Programming Page 5-3
Revised 10/14
Status Line
The status line is the top line of the display. It always lists the System Status, the Time
‐
of
‐
Day
and the Pump Status. It can also include the status of the Keypad (if locked) and the 7
‐
Day
Scheduler (if active). An example of an Overview Screen status line is seen below.
System Status
The status of the “system”, ie. the ASU (melter) and its hoses and applicators, is listed as one of
the following:
Pump Status
The status of the adhesive pump is indicated as follows:
Time
7
‐
Day Scheduler is active
Pump Status
System Status
Keypad is locked
HEAT
‐
UP
No faults present, zones are heating but haven't reached their setpoint window
READY
No faults present and all zones are within the setpoint window
ALARM
At least one zone is outside the setpoint window (over or under temp)
STANDBY
The system is in standby mode
OVER
‐
TEMP
The hopper is in over temperature condition, all power circuits are shut off
FAULT
A temperature zone has a fault and all power circuits are shut off or the motor drive has faulted
HOPPER EMPTY
Adhesive in the hopper is low and must be replenished
Temperature Zone Symbols
Each temperature zone is represented by a symbol on the display, as follows:
PUMPS
Pump has start signal and is actually running (seen on Overview Screen, upper right corner)
HOLD
Pump is in Run mode (auto or manual) but a low temperature condition prevents it from
running (seen on Overview Screen, upper right corner)
STOP
Pump is in Stop mode (seen on Pump Screen)
ASU's
Hopper
(up to 3)
(not used in the
D Series
configuration)
Hoses
(up to 12)
Applicator Heads
(up to 12)
ASU's
Premelt
(Drop
‐
in)
Grids
(up to 6)
Auxiliary Zones
(up to 12)
AUX-ZONE
Summary of Contents for DYNAMELT D15 Series
Page 3: ......
Page 4: ......
Page 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Page 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Page 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...