Page 7-10 Troubleshooting
Revised 10/14
ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
V6 Power Module PN 115732
The V6 POWER module provides controlled power to the heater of the first five zones. It receives
its control signals from the V6 TEMP module. The Power Module also has protected outputs for
the DC power supply and motor drive.
Each zone can provide a maximum of 10 Amps. The maximum total load of the board is 40 Amps
(20 per phase). The board has its own heat sink which is mounted on the panel box insert for good
heat conductivity.
Head 2
Heater
Hose 2
Heater
Head 1
Heater
Hose 1
Heater
Hopper
Heater
Motor Drive
DC Power
supply
Main Voltage Supply
(from main On/Off switch)
Power supply
for additional
power boards
Voltage
Configuration
Connector
Fuses (under
protective cover)
Connec
t to
V6 T
EMP Module
Current
Monitoring