Service functions and error messages
Page 124
Error message
Meaning of the error message
Measures
Main
index
Sub index
6
DC bus circuit discharge time exceeded Bridge for the internal brake resistor installed?
Check the connection of the external braking resistor.
If necessary, contact the Technical Support.
7
No power supply for the controller
enable signal
No DC bus circuit voltage?
Check the power supply.
If necessary, contact the Technical Support.
8
Power supply failure during the
controller enabling process
Check the power supply.
9
Phase failure
33
0
Following error, encoder emulation
Check the settings of the incremental encoder emulation
(number of lines).
If necessary, contact the Technical Support.
34
0
No synchronisation via the field bus
Failure of synchronization messages from master?
1
Field bus synchronisation error
Failure of synchronization messages from master?
Insufficient synchronisation interval?
35
0
Overspeed protection of the linear
motor
The encoder signals are disturbed. Check the installation for
compliance with EMC recommendations.
5
Error during the determination of the
commutation position
The selected method is not suitable for the motor. Please
contact the Technical Support.
36
0
Parameter limited
Check the user parameter set.
1
Parameter not accepted
40
0
Negative SW limit switch reached
Check the negative range limit.
1
Positive SW limit switch reached
Check the positive range limit.
2
Target position beyond the negative
SW limit switch
The start of a positioning run has been suppressed, since the
target is located beyond the respective software limit switch.
Check the target data.
Check the positioning range.
3
Target position beyond the positive SW
limit switch
41
0
Path program: synchronisation error
Check the parameterization.
If necessary, contact the Technical Support.