Technical data
Page 45
Table 17:
Controller C 1-08: Rated current for blocked or slowly rotated servo motor (f
el
)
≤
2 Hz and for an ambient temperature of
≤
40 °C
Parameter
Values
Power stage clock frequency (kHz)
≤
10
Output current (A
RMS
)
8
Max. output current (A
RMS
)
16
24
32
Max. allowed time (s)
5
0,7
0,2
Power stage clock frequency (kHz)
12
Output current (A
RMS
)
7,4
Max. output current (A
RMS
)
14,8
22,2
29,6
Max. allowed time (s)
5
0,7
0,2
Power stage clock frequency (kHz)
16
Output current (A
RMS
)
6,3
Max. output current (A
RMS
)
12,6
18,9
25,2
Max. allowed time (s)
5
0,7
0,2
Power stage clock frequency (kHz)
19
Output current (A
RMS
)
5,2
Max. output current (A
RMS
)
10,4
15,6
20,8
Max. allowed time (s)
5
0,7
0,2