Service functions and error messages
Page 126
Error message
Meaning of the error message
Measures
Main
index
Sub index
1
SDO error occurred
Please contact the Technical Support.
51
0
No or unknown FSM module or faulty
driver supply
Cause:
Internal voltage error of the safety module or of
the fieldbus activation module.
Action:
Module presumably defective. If possible,
replace with another module.
Cause:
No safety module detected or unknown module
type.
Action: Install safety or fieldbus activation module
appropriate for the firmware and hardware.
Load firmware appropriate for the safety or
fieldbus activation module, see type designation
on the module.
2
FSM: different module type
Cause:
Type or revision of the module does not fit the
project planning.
Action: Check whether correct module type and correct
version are being used.
With module replacement: Module type not yet
configured. Accept currently integrated safety or
fieldbus activation module.
3
FSM: different module version
Cause:
Type or revision of the module is not supported.
Action: Install safety or fieldbus activation module
appropriate for the firmware and hardware.
If only a module with a more recent version is
available: Load firmware that is appropriate for
the module, see type designation on the module.
Cause:
The module type is correct but the module
version is not supported by the basic device.
Action: Check module version; if possible use module of
same version after replacement. Install suitable
safety or fieldbus activation module for the
firmware and hardware.
If only a module with a more recent version is
available: Load firmware that is appropriate for
the module, see type designation on the module.