2.2
Front Panel LED
LED
Color
Status
Description
PWR
Green
On
DC power module up
PW1
Green
On
DC power module 1 activated.
PW2
Green
On
DC Power module 2 activated.
R.M
Green
On
Ring Master.
On
Ring enabled.
Ring
Green
Slowly blinking
Ring has only One link. (lack
of one link to build the ring.)
Fast blinking
Ring work normally.
Fault
Amber
On
Fault relay. Power failure or
Port down/fail.
Gigabit Ethernet ports
LNK/ACT
Green
On
100M/10M port is connected
Green
Blinking
100M/10M Data is transmitted
LNK/ACT
Amber
On
1000M port is connected
Amber
Blinking
1000M Data is transmitted
Gigabit SFP ports
LNK/ACT
Green
Blinking
Data is transmitted
On
Port link up
2.3
Bottom View of Panel
The Phillips Screw Terminal Block, located on the bottom of the unit, has Phillips screws with compression
plates, allowing either bare wire connections or crimped terminal lugs. The use of #6 size ring lugs is
recommended to ensure secure and reliable connections under severe shock or vibration. The terminal
block comes with a safety cover which must be removed before connecting any wires. This cover must
be re-attached after wiring to ensure personnel safety.
The iES12G series supports dual redundant power supplies (PWR1 and PWR2). There are 3 options:
•
LV: Dual Input 10-48VDC
•
MV: Single Input 36-75VDC with Single 10-48VDC Backup,
•
HV: Single Input 110-370VDC or 90
-
264VAC with Single 10-48VDC Backup
There are also connections for the Failsafe Relay. The Failsafe Relay is rated 1A @ 24VDC. Connections
to the Terminal block are listed in the table below.