Goodrive200A
inverters Function parameters
64
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.08
Frequency
coefficient
0.01~10.00
Displayed frequency=running frequency* P07.08
1.00
○
P07.09
Rotation
speed
coefficient
0.1~999.9%
Mechanical rotation speed =120*displayed
running frequency×P07.09/motor pole pairs
100.0%
○
P07.10
Linear speed
coefficient
0.1~999.9%
Linear speed= Mechanical rotation
speed×P07.10
1.0%
○
P07.11
Rectifier
bridge
module
temperature
0~100.0
℃
●
P07.12
Converter
module
temperature
0~100.0
℃
●
P07.13
Software
version
1.00~655.35
●
P07.14
Local
accumulative
running time
0~65535h
●
P07.15
High bit of
power
consumption
Display the power used by the inverter.
The power consumption of the inverter
=P07.15*1000+P07.16
Setting range of P07.15: 0~65535°(*1000)
Setting range of P07.16: 0.0~999.9°
●
P07.16
Low bit of
power
consumption
●
P07.17 Inverter type
0: G type
1: P type
●
P07.18
The rated
power of the
inverter
0.4~3000.0kW
●
P07.19
The rated
voltage of the
inverter
50~1200V
●
P07.20
The rated
current of the
inverter
0.1~6000.0A
●
P07.21
Factory bar
code 1
0x0000~0xFFFF
●
P07.22 Factory bar 0x0000~0xFFFF
●