Goodrive200A
inverters Function parameters
68
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
temperature
at previous 2
fault
P07.55
Input
terminals
state at
previous 2
fault
0
●
P07.56
Output
terminals
state at
previous 2
fault
0
●
P08 Group Enhanced function
P08.00 ACC time 2
Refer to P00.11 and P00.12 for detailed
definition.
Goodrive200A series define four groups of
ACC/DEC time which can be selected by P5
group. The first group of ACC/DEC time is the
factory default one.
Setting range:0.0~3600.0s
Depend
on
model
○
P08.01 DEC time 2
Depend
on
model
○
P08.02 ACC time 3
Depend
on
model
○
P08.03 DEC time 3
Depend
on
model
○
P08.04 ACC time 4
Depend
on
model
○
P08.05 DEC time 4
Depend
on
model
○
P08.06
Jogging
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00Hz ~P00.03
(the Max. frequency)
5.00Hz
○
P08.07
Jogging ACC
time
The jogging ACC time means the time needed if
the inverter runs from 0Hz to the Max.
Frequency.
The jogging DEC time means the time needed if
the inverter goes from the Max. Frequency
(P0.03) to 0Hz.
Depend
on
model
○
P08.08
Jogging DEC
time
Depend
on
model
○