inverters Installation guidelines
14
4.2.3 Installation manner
The inverter can be installed in two different ways, depending on the frame size:
a) Wall mounting (for the inverter≤315kW)
b) Flange mounting (for the inverter≤200kW). Some need optional flange installation board.
c) Floor mounting (220kW≤the inverter≤500kW). Some need optional base.
Fig 4-2 Installation manner
(1) Mark the hole location. The location of the holes is shown in the dimension drawings in
the appendix.
(2) Fix the screws or bolts to the marked locations.
(3) Position the drive onto the wall.
(4) Tighten the screws in the wall securely.
Note:
1. The flange installation bracket is needed in the flange installation of 1.5~30kW inverters,
which the flange installation of 37~200kW inverters does not need the installation bracket.
2. 220~315kW inverters need optional base in the floor installation.
4.2.4 Multiple installations
Parallel installation
Fig 4-3 Parallel installation
Note:
Before installing the different sizes inverters, please align their top position for the
convenience of later maintenance.