20
1.
Remove the plastic cover from the processor socket on the server board
Figure 30. Plastic processor socket cover removal
Grasp the processor cover as shown in the following figure (see Letter A)
Carefully pull it up away from the processor socket, ensuring no contact is made with any of the pins
within the socket. (see Letter B)
NOTE
: The processor socket cover should be saved for future use.
CAUTION:
When re-installing the socket cover, make sure it properly snaps into place. Improper installation
will cause it to become loose and damage the processor socket.
The
assembled
PHM and the processor socket include several alignment features to ensure the PHM can
only be installed one way. Care should be taken to ensure components are accurately assembled and the
PHM is oriented correctly to the processor socket prior to placement onto the server board.
Figure 31. Alignment Features
Screw #1
(Pin #1)
Wide Alignment
Guide Pin
Wide Alignment
Guide Hole
Narrow Alignment
Guide Pin
Narrow Alignment
Guide Hole