Appendix E.
POST Code Errors
Most error conditions encountered during POST are reported using
POST Error Codes
. These codes
represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error
Manager Display screen, and are always logged to the System Event Log (SEL). Logged events are available to
System Management applications, including Remote and Out of Band (OOB) management.
There are exception cases in early initialization where system resources are not adequately initialized for
handling POST Error Code reporting. These cases are primarily Fatal Error conditions resulting from
initialization of processors and memory, and they are handed by a Diagnostic LED display with a system halt.
The following table lists the supported POST Error Codes. Each error code is assigned an error type which
determines the action the BIOS will take when the error is encountered. Error types include Minor, Major,
and Fatal. The BIOS action for each is defined as follows:
Minor:
The error message is displayed on the screen or on the Error Manager screen, and an error is
logged to the SEL. The system continues booting in a degraded state. The user may want to replace the
erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error.
Major:
The error message is displayed on the Error Manager screen, and an error is logged to the SEL.
The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error
Manager for this type of error so the user can take immediate corrective action or the system continues
booting.
Note that for 0048 “Password check failed”, the system halts, and then after the next reset/reboot will
displays the error code on the Error Manager screen.
Fatal:
The system halts during post at a blank screen with the text “Unrecoverable fatal error found.
System will not boot until the error is resolved” and “Press <F2> to enter setup” The POST Error Pause
option setting in the BIOS setup does not have any effect with this class of error.
When the operator presses the
F2
key on the keyboard, the error message is displayed on the Error Manager
screen, and an error is logged to the SEL with the error code. The system cannot boot unless the error is
resolved. The user needs to replace the faulty part and restart the system.
Note:
The POST error codes in the following table are common to all current generation Intel server
platforms. Features present on a given server board/system will determine which of the listed error codes
are supported
Table 9. POST Error Codes and Messages
Error Code
Error Message
Action message
Response
0012
System RTC date/time not set
Major
0048
Password check failed
Please put right password.
Major
0140
PCI component encountered a PERR error
Major
0141
PCI resource conflict
Major
0146
PCI out of resources error
Please enable Memory
Mapped I/O above 4 GB item at SETUP to
use 64bit MMIO.
Major
0191
Processor core/thread count mismatch detected
Please use identical CPU type.
Fatal
0192
Processor cache size mismatch detected
Please use identical CPU type.
Fatal