Chapter 4 Assembly and function
!
WARNING
Water jet.
Risk of injury and risk of property damage due to es-
caping water.
1. Interrupt the external water supply by closing the water
valve.
2. In order to release the pressure (approx. 2 bar), open
the water drainage valve on the water measuring sys-
tem under the pressure reducer.
3. Remove the hose from the external water supply.
4. Do not point the water jet at other people or yourself.
4.5.6 Air fitting
1
2
3
4
Description of the components in the diagram
Item
Component
1
Compressed air control, 1 - 4 bar
2
GEKA coupling for connecting the air hose
3
Pneumatic hose for connecting to the com-
pressor
4
EWO coupling
4.6 Connections
4.6.1 Power connections (230 V)
1
2
3
4
Connection socket for the booster pump (optional) (1), con-
nection socket for the motor (2), connection socket for the
optional compressor (3) and 3-pole power supply plug (4) to
the external power supply (AC 230 V).
4.6.2 Water fitting connections
1
2
Connection for an external cleaning hose or con-
nection of the conveyor hose via a coupling piece
for cleaning the hose by means of a sponge ball (1),
connection of the external water supply (2).
Summary of Contents for inoCOMB Picco Power
Page 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Page 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Page 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Page 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...
Page 46: ...Page 46 EN Chapter 13 Systems 13 3 5 Switching cabinet outside...