Page 35
EN
Chapter 11 Maintenance
11.2 Dirt trap sieve in the water inlet
(Brass sieve insert, item no. 10006007)
1
1. Remove the dirt trap sieve (1) from the GEKA coupling.
2. Clean the dirt sieve trap daily.
3. Replace the dirt trap if it is very dirty.
4. Re-install the dirt trap sieve.
11.3 Dirt trap sieve in the pressure reducing valve
(replacement strainer for pressure reducer item no.
10006518)
1
2
1. Unscrew the sieve cup (1) from the pressure reducer.
2. Remove and clean the dirt trap sieve (2) once a month.
3. Replace the dirt trap if it is very dirty.
4. Install a new dirt trap sieve and screw the sieve cup onto
the pressure reducer.
11.4 Set values
Water pressure switch
ON: 2.1 bar
Off: 2.0 bar
Air pressure switch
ON: 1.7 bar
Off: 2.7 bar
Pressure reducer
2.2 bar
Protection type
IP 54
11.5 Wear limit for mixing coils
Maximum height of mixer
blades:
30 mm
Minimum height of mixer
blades
(wear limit)
25 mm
12 Faults, causes and solutions
The inoCOMB Picco Power is designed for fault-free op-
eration. However, should a fault occur, please follow the
instructions below on analysing, checking and remedying
the fault or contact the Inotec Service team (see the address
list for INOTEC service centres at the end of the document)
or call the INOTEC service hotline on: +49 7741 6805 777.
WARNING
Faults can put the safety of operating staff
at risk and impair the functionality of the machine.
Proceed as follows where a fault occurs:
1. Cut off the power supply in the event of any faults
which pose a direct risk to people or material assets. To
do this, press the red pushbutton.
2. Pull out the mains plug.
3. Secure the machine against unexpectedly being
switched back on
4. Determine the cause of the fault.
5. Report the fault to the responsible person on site.
6. Depending on the type of fault you can either rectify
this yourself or have it rectified by a qualified electrical
specialist.
The faults listed below feature recommendations as
to who is authorised to rectify the fault.
Summary of Contents for inoCOMB Picco Power
Page 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Page 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Page 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Page 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...
Page 46: ...Page 46 EN Chapter 13 Systems 13 3 5 Switching cabinet outside...