![InoTec inoCOMB Picco Power Original Operating Manual Download Page 9](http://html1.mh-extra.com/html/inotec/inocomb-picco-power/inocomb-picco-power_original-operating-manual_2064544009.webp)
Page 9
EN
Chapter 3 Technical data
2.5 Responsibility of the operator
• Only task trained or instructed staff with operating the
inoCOMB Picco Power.
• Define employees’ responsibilities for operating, setting
up, maintaining and servicing the machine clearly.
• Only task untrained staff or individuals who have not re-
ceived any instruction with operating the machine when
there is a trained or instructed specialist available to su-
pervise them.
• Work on the electronic control system may only be per-
formed by a qualified electrician.
2.6 Personal protective equipment (PPE)
!
CAUTION
PPE – particularly gloves, safety boots, a
safety helmet and safety goggles and respiratory pro-
tection – must be used.
3 Technical data
3.1 Rating plate
1
5
4
2
3
Item Component
Value
1
Manufacturer, address and contact
details, CE marking
-
2
Name and type of machine
-
3
Machine’s year of construction
-
4
Machine number
-
5
Technical data
- Voltage
- Current
- Output
230 V
16 A
3.0 kW
You must always state the machine number if you would
like to order spare parts, have any queries or would like
to make a complaint. You will find this information on the
rating plate or on the delivery note.
3.2 Electric control system, pump output, particle size,
weight, dimensions
Mains voltage
230 V, 50 Hz
Mains supply line (CEE plug)
16 A (to be supplied by
customer)
Output
3.0 kW
(frequency-controlled)
Fuse
min. 16 A
Delivery rate*
approx. 0-18 l/min.
past-like
approx. 8-30 l/min.
mineral
Delivery range*
up to 30 m
Delivery height*
up to 20 m
external (without compressor) approx. 65 kg
Dimensions:
Length
1,560 mm
Width
640 mm
Height
1,090 mm
* Material-dependent and depending on the consistency of the material –
Observe the material manufacturer’s instructions.
Summary of Contents for inoCOMB Picco Power
Page 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Page 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Page 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Page 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...
Page 46: ...Page 46 EN Chapter 13 Systems 13 3 5 Switching cabinet outside...