Chapter 11 Maintenance
Symptom
Potential cause
Check / solution
Personnel
qualification
If the machine will not
start.
Power supply is
cut off.
• Check the power supply (power distribution points, socket,
power cable, cable reel).
Machine
operator
No input voltage
available.
• Have the voltage supply checked at the worksite distribution
board, supply cables and cable reels.
• Have the voltage supply restored if it was interrupted.
Qualified
electricians
Blockage due to
foreign bodies or
hardened material in
the mixing pipe or
rotor/stator
• Remove the foreign bodies and clean the mixing pipe or rotor/
stator
Machine
operator
Water pressure too
low
• Check the water pressure at the pressure gauge of the water
fitting (min. 2.5 bar)
• Use a water pressure booster pump if the water pressure is
too low.
Machine
operator
The machine has
stopped.
The overcurrent
protection device has
tripped.
• Check the RC fault indicator on the switching cabinet.
• This fault lamp lights up if there is a fault in the frequency
inverter! Press this switch.
Machine
operator
• Have the motor checked.
• Have the fault remedied if necessary.
Service
technician/
qualified
electrician
The machine has
stopped.
Mixing coil mechani-
cally blocked.
• Check whether any foreign bodies are in the mixing coil; if
necessary, remove the foreign bodies.
Machine
operator
The machine has
stopped.
Rotor/stator mechani-
cally blocked.
• Check whether any hardened material or foreign bodies are
in the rotor/stator; if necessary, remove the hardened material
or foreign bodies.
Machine
operator
The motor is running
irregularly or the ma-
chine is in fault mode.
The machine is run-
ning at its limits;
the motor is drawing
11 A current;
the RC is regulating
the motor.
• Reduce the rotation speed, and also the water quantity ac-
cordingly.
Machine
operator
Too little water
• When starting the machine, open the needle valve a little
more
• If necessary, switch off the machine from the main switch, and
then switch it on again after approx. 30 seconds (reset).
Machine
operator
Material too rigid
• Never open the device during operation
• If necessary, switch off the machine from the main switch, and
then switch it on again after approx. 30 seconds (reset).
Excessively high deliv-
ery pressure
• Reduce hose length
• If necessary, switch off the machine from the main switch, and
then switch it on again after approx. 30 seconds (reset).
Only water comes out
of the mixing pipe
outlet
The mixing coil is not
connected to the
rotor/stator.
• Check if the mixing pipe is mounted properly.
• Check that the mixing coil is connected to the rotor/stator.
Machine
operator
Summary of Contents for inoCOMB Picco Power
Page 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Page 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Page 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Page 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...
Page 46: ...Page 46 EN Chapter 13 Systems 13 3 5 Switching cabinet outside...