Page 28
EN
Chapter 6 Installation
6.3 Installing the mixing coil
1. Open the eccentric lock (1) that connects the motor to
the material hopper and move the motor away to the
side.
2. Push the mixing coil (2) into the material hopper.
3. Re-attach the motor (3) to the material hopper by
means of the eccentric lock, and ensure that the mix-
ing coil is connected to the motor and the rotor of the
pump unit.
3
1
2
6.4 Connecting the compressor
1. Place the compressor onto the support bracket provid-
ed on the base frame of the machine.
2. Connect the yellow air hose to the compressor.
3. Insert the connector plug into the connection socket on
the switching cabinet.
6.5 Connecting the electrical control system
1. Connect the inoCOMB Picco Power only to regulation
230 V construction site power distribution points with FI
circuit breakers (30 mA) (RCD).
2. Ensure that the connection is protected by a 16 A fuse
and that the cross-section of the supply cable is at least
2.5 mm
2
.
3. Insert the supply cable into the input connector plug (1)
on the switching cabinet.
4. Set the main switch to vertical (= ON)
1
3-pole power supply plug (1)
6.6 Installing the water measuring system
1. Connect the supply hose to the external water supply.
2. Open the water valve until a steady water jet comes out
of the hose in order to both clean the water hose of dirt
and ventilate it.
3. Then close the water valve on the external water supply.
4. Connect the external water hose to the GEKA coupling
of the water fitting (1) below the pressure gauge.
5. Close both the water drainage valve (2) below the pres-
sure reducer and below the flow meter.
1
2
6. Open the water valve of the external water supply and
check on the pressure gauge whether the minimum
water pressure of 2.5 bar can be guaranteed (if the
external water pressure is lower than 2.5 bar, the ma-
chine goes into fault mode and the fault indicator on
the switching cabinet flashes red). Water pressure that
is too low can be remedied by an optional water pres-
sure booster pump.
7. Detach the internal water hose from the yellow mixing
zone and place it in a bucket.
8. Acknowledge the red flashing fault display by press-
ing the “Fault” illuminated pushbutton. The indicating
light then lights up green “Ready for operation”.
9. Then press and hold down the button for the “Water
inlet” until the process has been completed. In doing
so, water flows from the end of the internal water hose
into the bucket. Simultaneously turning the setting dial
of the needle valve enables you to set the desired or
required water quantity for the optimum mixing con-
sistency. Turn the setting dial to the left to increase the
amount of water (the float in the water inspection glass
rises) – turn to the right to reduce the water quantity
(the float in the water inspection glass drops).
Summary of Contents for inoCOMB Picco Power
Page 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Page 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Page 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Page 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...
Page 46: ...Page 46 EN Chapter 13 Systems 13 3 5 Switching cabinet outside...