Chapter 6: Maintenance and troubleshooting
98-122988-E
170
01900 to
01909
Temperature
too low for
charging
The temperature is too low
for the battery charger to
operate.
If charging is needed, move
the EXPLORER 700 to a
warmer location. The
temperature must be above
0°C/+32°F for the battery
charger to operate.
02000 to
02009
Satellite
signal weak
The signal from the satellite
is weak.
Check the line of sight to
the satellite. Be aware that
window glass may reduce
the signal level.
Check that the antenna is
pointed according to the
position data. Adjust the
position to the highest
possible signal strength.
02100 to
02109
Ciphering off
The network has turned
ciphering off.
Do not transmit data that
requires ciphering.
02200 to
02209
Ethernet
connection
failed
Ethernet data session could
not be established.
See the display call log for
the cause of the error.
Refer to Calls menu on
page 43.
If the problem persists,
contact your distributor.
02400 to
02409
Invalid
battery
The EXPLORER 700 is not
able to detect the battery
type.
The reason may be one of
the following:
•
You are not using an
original Thrane &
Thrane battery
•
The battery is defective
The EXPLORER 700
requires an original Thrane
& Thrane battery.
If you are already using an
original Thrane & Thrane
battery when you see this
alarm, contact your
distributor for support.
02600 to
02609
Antenna
failure
Calibration data lost
Do not use the
EXPLORER 700. Contact
your distributor.
ID
Alarm Text
Explanation
Remedy