HD2 IP55 High-ingress Protection Series Inverters
Basic Operation Instructions
-47-
5.5.2 Common commissioning procedures
The common operation procedures are shown below (take motor 1 as an example).
Asynchronous motor Synchronous motor
Complete parameter rotary
autotuning
Complete parameter static
autotuning
Partial parameter rotary
autotuning
Note:
If fault occurred, rule out the fault cause according to "fault tracking".
Start autotuning after pressing
RUN key, and stop after
autotuning is done
Set running command channel
(P00.01, P00.02)
Start
Power up after confirming the
wiring is correct
Restore to default value
(P00.18=1)
Press QUICK/JOG to jog
Set the motor parameters of
P02.15
–
P02.19 as per the
motor nameplate
Set the motor parameters of
P02.01
–
P02.05 as per the
motor nameplate
Set autotuning mode
(P00.15)
If the motor rotates in wrong direction, power off
and exchange the motor wires of any two phases,
and power on again
Set running frequency
SVPWM control mode
(P00.00=2)
SVC 2 (P00.00=1)
SVC 1 (P00.00=0)
Set speed running control
mode (P00.00)
Set start/stop control
parameters in P01 group
Set V/F parameters in P04
group
Set vector control parameters
in P03 group
Set vector control parameters
in P03 group
Run after running command
Stop after stop command
End
Summary of Contents for HD2 IP Series
Page 1: ......
Page 16: ......
Page 40: ......
Page 107: ......
Page 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Page 213: ......
Page 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Page 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Page 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Page 361: ......