Function
code
Name
Description
Default
value Modify
and maintains the power balance by droop
control)
1: Master/slave mode 1
(The master and slave must be in the same
type of vector control mode. The master is
speed control, and the slave will be forced to
be in the torque control mode.
2: Master/slave mode 2
Start in the slave first speed mode
(master/slave mode 0) and then switch to
torque mode at a certain frequency point
(master/slave mode 1)
Tens: Slave start command source selection
0: Follow the master to start
1: Determined by
P00.01
Hundreds: Slave transmitting/master receiving
data enable
0: Enable
1: Disable
P28.03
Slave speed
gain
0.0–500.0%
100.0%
○
P28.04 Slave torque
gain
0.0–500.0%
100.0%
○
P28.05
Master/slave
mode 2 speed
mode / torque
mode switching
frequency point
0.00–10.00Hz
5.00Hz
○
P28.06
Number of
slaves
0–15
1
◎
P28.07–
P28.29
Reserved
/
/
/
Function
code
Name
Descripti
on
Default
value Modify
P30 PID1 group
P30.00
Unit
0
:
bar
1
:
kbar
2
:
MPa
3
:
kPa
4
:
Pa
5
:
A
6
:
V
7
:
%
0
◎
Summary of Contents for HD2 IP Series
Page 1: ......
Page 16: ......
Page 40: ......
Page 107: ......
Page 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Page 213: ......
Page 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Page 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Page 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Page 361: ......