HD2 IP55 High-ingress Protection Series
Function parameter list
-115-
P00 group––Basic functions
Function
code
Name
Description
Default
value Modify
P00.00 Speed control
mode
0: SVC 0
1: SVC 1
2: SVM
3: VC
Note:
If 0, 1 or 3 is selected, it is required to
carry out motor parameter autotuning first.
2
◎
P00.01
Running
command
Source
0: Keypad
1: Terminal
2: Communication
0
○
P00.02
Communicati
on running
command
channel
0: Modbus
1: PROFIBUS/CANopen/DeviceNet
2: Ethernet
3: EtherCAT/PROFINET
4: PLC programmable card
5: Wireless communication card
Note:
1, 2, 3, 4 and 5 are extended functions
which are applicable with corresponding cards.
0
○
P00.03 Max. output
frequency
Used to set the max. output frequency of the
inverter. It is the basis of frequency setup and the
acceleration/deceleration.
Setting range: Max (
, 10.00) –630.00Hz
50.00Hz
◎
P00.04
Upper limit of
running
frequency
The upper limit of running frequency is upper limit
value of inverter output frequency. This value
should be no more than the max. output
frequency.
When the set frequency is higher than the upper
limit frequency, the inverter runs at the upper limit
frequency.
Setting range:
(max. output
frequency)
50.00Hz
◎
P00.05
Lower limit of
running
frequency
The lower limit of running frequency is the lower
limit value of inverter output frequency.
When the set frequency is lower than the lower
limit frequency, the inverter runs at the lower limit
frequency.
Note:
Max. output frequency
≥
upper limit
frequency
≥
lower limit frequency.
Setting range: 0.00Hz–
(upper limit of
running frequency)
0.00Hz
◎
P00.06
A frequency
command
selection
0: Set via keypad
1: Set via AI1
2: Set via AI2
3: Set via AI3
4: Set via high speed pulse HDIA
5: Set via simple PLC program
0
○
P00.07
B frequency
command
selection
15
○
Summary of Contents for HD2 IP Series
Page 1: ......
Page 16: ......
Page 40: ......
Page 107: ......
Page 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Page 213: ......
Page 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Page 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Page 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Page 361: ......