58
STHCkW ed 0409
HERCULES Condensing Export
Technical Documentation
Technical Documentation
HERCULES Condensing ABT 32 2 I technical data.
- Fume temperature values refer to an air inlet temperature of
15°C.
- The data relevant to domestic hot water performance refer to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
the values are measured directly at the boiler outlet considering that
to obtain the data declared mixing with cold water is necessary.
- The maximum sound level emitted during boiler operation is <
55dBA. The sound level value is referred to semianechoic chamber
tests with boiler operating at max. heat output, with extension of
fume exhaust system according to product standards.
Domestic hot water nominal heat input
kW (kcal/h)
33,0 (28392)
Central heating nominal heat input
kW (kcal/h)
33,0 (28392)
Minimum heat input
kW (kcal/h)
7,3 (6279)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
32,0 (27520)
Central heating nominal heat output (useful)
kW (kcal/h)
32,0 (27520)
Minimum heat output (useful)
kW (kcal/h)
6,9 (5934)
Efficiency 80/60 Nom./Min.
%
96,9 / 94,5
Efficiency 50/30 Nom./Min.
%
104,7 / 105,8
Efficiency 40/30 Nom./Min.
%
107,3 / 107,3
Heat loss at casing with burner On/Off (80-60°C)
%
0,75 / 0,20
Heat loss at flue with burner On/Off (80-60°C)
%
0,03 / 2,90
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Max. adjustable central heating temperature
°C
25 - 85
Min. adjustable central heating temperature
°C
25 - 50
System expansion vessel total volume
l
10,8
Heating expansion tank pre-charge
bar
1,0
Total volume domestic hot water expansion vessel
l
4,1
Domestic hot water expansion vessel pre-charge
bar
3,5
Water content in generator
l
6,9
High temperature zone total head available with 1000/h flow rate
kPa (mm H
2
O)
30,87 (3,15)
Low temperature zone total head available with 1000/h flow rate
kPa (mm H
2
O)
35,28 (3,60)
Hot water production useful heat output
kW (kcal/h)
32,0 (27520)
Domestic hot water adjustable temperature
°C
20 - 60
Domestic hot water flow limiter
l/min
30,0
Min. pressure (dynamic) domestic hot water circuit
bar
0,3
Domestic hot water circuit max. working pressure
bar
8,0
*Specific capacity “D” according to EN 6625
l/min
24,3
Drawing capacity in continuous duty (∆T 30°C)
l/min
16,0
Domestic hot water performance classification according to N 13203-1
Weight of full boiler
kg
256,4
Weight of empty boiler
kg
130,1
Electrical connection
V/Hz
230 / 50
Power input
A
1,06
Installed electric power
W
200
Pump consumption
W
61
Fan consumption
W
26,4
Equipment electrical system protection
-
IPX5D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
52
Weighted CO
mg/kWh
17
Type of appliance
C13 / C33 / C43 / C53 / C83 / B23 / B33
Category
II2H3B/P