65
STHCkW ed 04/09
HERCULES Condensing Export
Technical Documentation
Technical Documentation
03
b
Flue evacuation takes place correctly.
No
Clean/restore the correct functionality of the flue extraction elements,
checking lengths and any obstructions.
Clean/restore the correct functionality of the condensation module
checking that there are no combustion impurities deposited on the heat
exchanger (soot, oxidations, etc..).
Yes
If the anomaly persists, replace the P.C.B.
ERROR 04
Contacts resistance block
04
The overheating safety thermostat functions regularly.
No
Check the wiring and cleanliness of the electric connection, the continuity
of the thermostat contact and replace if necessary.
Yes
The connector and relative wiring between gas valve and P.C.B.
are OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the gas valve. If the anomaly persists, replace the P.C.B.
ERROR 05
Flow probe anomaly
05
The wiring between the flow probe and the board (connector X9
terminals 10-11) is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the NTC flow probe. If the anomaly persists, replace the P.C.B.
ERROR 10
Insufficient system pressure
10
The boiler manometer displays a pressure exceeding 0.8 bar.
No
Restore the correct pressure by acting on the system filling valve.
N.B.: in this case it is always advisable to ensure that there are no leaks
in the central heating plant and check the correct factory-set value of the
expansion vessel.
Yes
The wiring between the absolute pressure switch and the board is OK. No
Restore the electric connection/replace the wiring.
Yes
Check/replace the system pressure switch. If the anomaly persists, replace the P.C.B.
ERROR 12
Storage tank probe anomaly
The boiler prevents functioning in DHW mode but can function in CH mode.
12
The wiring between the storage tank probe and the board (connector
X9 terminals 6-7) is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the storage tank NTC probe. If the anomaly persists, replace the P.C.B.
ERROR 15
The boiler could display the 06 error
Wiring configuration error
N.B.: This board can be used for instant type boilers (VICTRIX Superior kW)
or with storage tank (VICTRIX ZEUS Superior kW ). The board automatically
recognises the type of boiler by means of the relative wiring of the P.C.B.
15
The board is configured as boiler with storage tank.
(presence of the jumper between clamps 6-7 of the connector X7).
No
For the HERCULES Condensing boiler check the PRESENCE of the
connection jumper between clamps 6-7 of the connector X7.
Yes
Replace the P.C.B.