46
STHCkW ed 0409
HERCULES Condensing Export
Technical Documentation
Technical Documentation
Outputs.
It allows the connection of electronic devices, e.g. Immergas zones digital control unit.
IMG BUS connection
(optional)
It is a signal (BUS) that shows boiler temperature, functioning in DHW and Ch mode,
the alarm codes that have intervened and the temperature detected by any external probe
on the remote control display.
Comando Amico Remoto
remote control (CAR)
(optional) (see CAR functioning)
It is a relay that allows to power the motor (M) of the electric 3-way valve (M30). It is
excited with a central heating request and remains in stand-by with a domestic hot water
request.
Three-way valve relay
(K4)
It is a signal (BUS) that shows boiler temperature, functioning in DHW and Ch mode,
the alarm codes that have intervened and the temperature detected by any external probe
on the remote control display.
Super CAR
(optional)
It is a unipolar relay that is excited when burner ignition is necessary. The electric spark takes
place at the ends of the ignition electrodes positioned on the burner, due to its contact.
Igniter relay
(K7)
It is a unipolar relay that allows to power the gas valve coils when the boiler must be
ignited.
Gas valve relay
(K3)
It is a unipolar relay for boiler pump control (M1) that is excited when its functioning
is requested.
Boiler pump relay
(K2)
It is a positive square wave signal with variable ON-OFF relationship (duty-cycle) that
controls the fan.
Allows to vary the air flow rate to the Venturi pipe and therefore the gas pressure to the
burner.
Fan
It is a 24 V DC signal that indicates the power supply of the main coils of the gas valve.
Gas valve power supply
(Y1)