HERCULES Condensing Export
Technical Documentation
Technical Documentation
Allows the integrated P.C.B. to detect the temperature of the pri-
mary circuit flow water.
Its breakage (signalled by relative anomaly) blocks burner functioning
both in central heating and domestic hot water modes.
It is positioned at the outlet of the main heat exchanger.
Flow probe
(B1)
NTC probe
10 kΩ 25 °C
It allows the integrated P.C.B. to detect the temperature of the
exiting domestic hot water.
Its breakage (signalled by relative anomaly) allows the boiler to
continue working in the central heating mode.
It is inserted into a hole made on the outside wall of the storage
tank to which it is fixed.
Domestic hot water probe
(B2)
NTC probe
10 kΩ 25 °C
Detects the external temperature and allows the integrated
P.C.B. to vary the flow temperature depending on the external
temperature.
External probe
(B4) (optional)
PTC probe
1 kΩ 25 °C
Low voltage circuit.
Safety devices and controls.
When the pressure of the boiler circuit is below 0.3 bar it determines
burner switch-off.
System pressure switch
(S5)
Contact in
Shut-off
It is a resistance that simulates the presence of the system return
probe. It must always be present.
Return probe resistance
(R9)
Factor
2,2 kΩ 1/4 W
Allows long distance control of the generator (SUM/WIN selector
switch, temperature adjustment and indication, alarms display, reset,
etc.) and acts as weekly timer thermostat.
If the CAR is installed the pre-existing X40 jumper must be
eliminated.
Comando Amico Remoto
remote control
(CAR) (optional)
See Comando
Amico Remoto
remote control
functioning
(CAR)
Allows long distance control of the generator (SUM/WIN fun-
ctioning, temperature adjustment and indication, programs and
parameters setting alarms display, reset, etc.) and acts as weekly timer
thermostat.
If the Super CAR is installed the pre-existing X40 jumper must
be eliminated.
Super CAR
(optional)
See Super CAR
functioning
It is mounted on the front inside the boiler in the top right part.
In the case of assembly of the additional zones management kits,
the board controls all electric devices connected to it (e.g. motorised
mixing valves, pumps, NTC probes, safety thermostats etc).
N.B.: in the HERCULES Condensing ABT model, the zones
digital control unit is supplied as per standard.
Zones digital control unit
IMG BUS connection
(optional)
See functioning
technical sheet
Zones digital
control unit