Fault and anomaly signals.
Anomaly signalled
Error code display
Super CAR display
Car display
No ignition block
ERR 01
ERR 01
E01
Safety thermostat block (over-heating), flame control
anomaly
ERR 02
ERR 02
E02
Flue safety thermostat block
ERR 03
ERR 03
E02 + E03
Contacts resistance block
ERR 04
ERR 04
E02 + E04
Flow probe anomaly
ERR 05
ERR 05
E05
Insufficient system pressure
ERR 10
ERR 10
E10
Domestic hot water probe anomaly
ERR 12
ERR 12
E12
Configuration error
ERR 15
ERR 15
E15
Fan anomaly
ERR 16
ERR 16
E16
Parasite flame block
ERR 20
ERR 20
E02 + E20
Zones control unit anomaly (displayed only on CAR
or Super CAR remote control when the boiler displays he
errors from 32 to 36)
ERR from 32 to 36
ERR 22
E22
Return probe anomaly
ERR 23
ERR 23
E23
Push button control panel anomaly
ERR 24
ERR 24
E24
Insufficient circulation
ERR 27
ERR 27
E27
Loss of remote control communication
ERR 31
ERR 31 / CM
E31 / CON
Low temperature zone 2 probe anomaly
ERR 32
ERR 22
E22
Low temperature zone 3 probe anomaly
ERR 33
ERR 22
E22
Low temp. zone 2 safety thermostat intervention.
ERR 34
ERR 22
E22
Low temp. zone 3 safety thermostat intervention.
ERR 35
ERR 22
E22
IMG Bus communication loss
ERR 36
ERR 22
E22
Low power supply voltage
ERR 37
not displayed
not displayed
Loss of flame signal
38
(displayed only on VIRGILIO palmtop, or inside the "M1"/ "P19"
menu)
The HERCULES Condensing boiler signals any anomalies
by the flashing symbol (5) along with the “ERRxx” indica-
tion on the indicator (6) where “xx” corresponds to the error
code described in the following table. To eliminate the block
(where necessary), press the RESET "C" button positioned on
the boiler panel.
6
5