7
STHCkW ed 04/09
HERCULES Condensing Export
Technical Documentation
Technical Documentation
HERCULES Condensing ABT hydraulic diagram.
Key:
1 - Stainless steel coil for storage tank
2 - System draining valve
3 - Polyphosphate dispenser (optional)
4 - System filling valve
5 - 3 bar safety valve
6 - Manifold draining valve
7 - Condensate drain trap
8 - Gas valve
9 - Gas valve outlet pressure point (P3)
10 - Air intake pipe
11 - Fan
12 - Gas nozzle
13 - Detection electrode
14 - Burner
15 - Flue safety thermostat
16 - Condensation module covers
17 - Condensation module
18 - Manual air vent valve
19 - Flue hood
20 - Air sample point
21 - Flue sample point
22 - Pressure point ΔP gas
23 - Flow probe
24 - Safety thermostat
25 - Ignition electrode
26 - Boiler Pump
27 - System pressure switch (absolute)
28 - Three-way valve (motorised)
29 - Venturi positive sign P1
23 - Venturi negative sign P2
31 - Air/gas Venturi manifold
32 - System expansion vessel
33 - Vent valve
34 - Hydraulic manifold
35 - Low temp. zone one-way valve
36 - Low temp. zone mixing valve
37 - Low temperature zone system pump
38 - Low temperature safety thermostat
39 - Low temp. zone flow probe
40 - Low temp. zone automatic by-pass
41 - High temperature zone system pump
42 - High temp. zone one-way valve
43 - High temp. zone automatic by-pass
44 - D.H.W. expansion vessel
45 - Cold water inlet cock
46 - Cold water inlet filter
47 - Flow limiter
48 - Cold water inlet non-return valve
49 - 8 bar safety valve
50 - DHW recirculation pump (optional)
51 - Domestic hot water probe
52 - Magnesium anode
53 - Storage tank unit draining valve
RB - Low temperature zone system return
MB - Low temperature zone system flow
RA - High temperature zone system return
MA - High temperature zone system flow
G - Gas supply
AC - Domestic hot water outlet
AF - Domestic hot water inlet
RC - Domestic hot water recirculation
RP - Return from solar panels
MP - Flow from solar panels
Summary of Contents for Hercules Condensing 26 2 E