52
STHCkW ed 0409
HERCULES Condensing Export
Technical Documentation
Technical Documentation
1st
Level
Button
2nd Level
Button
3rd Level
Button
Description
M1 (INFO)
D
C
P11
(SOFTWARE)
D
C
Displays the management software version of the circuit board installed
in the boiler
P12
(HEAT.TIME)
Displays the total operating hours of the boiler
P13
(IGNIT.NR)
Displays the number of burner ignitions
P14
(OUTSIDET.)
(with optionall
external probe
present)
--
(NO EXT.P.)
(without optional
external probe
present)
D
C
P14/A
(CURRENT)
Displays the current external temperature (if external probe is present
Optional)
P14/B
(OUT T.MIN)
Displays the minimum external temperature recorded (if external probe is
present Optional)
P14/C
(OUT T.MAX)
Displays the maximum external temperature recorded (if external probe is
present Optional)
RESET
D
x
selection
C
By pressing button“D” the MIN and MAX temperatures measured are
reset
P15
(DHW FLOW)
D
C
No display for this model
P17
(FANSPEED)
Displays the speed in instantaneous revs of the fan
P18
(PUMPSPEED)
The value displayed does not affect this model
P19
(FAILURE)
Displays the last 5 events that have caused the boiler to shutdown
The sequential number from 1 to 5 along with the relative error code
By pressing button “D” repeatedly, it is possible to display opeating times
and the number of ignitions where the anomaly took place
Information menu M1 (INFO).
This menu contains the
various information relative to boiler operations:
1st
Level
Button
2nd Level
Button
3rd Level
Button
4th Level
Button
Description
M3 (P
ERS. MENU)
D
C
P31
(DISPLAY)
D
C
(LIGHT)
AUTO
(Default)
D
x
selection
C
The display lights up when the burner is
on and when the controls are accessed.
It remains on for 5 seconds after the last
operation performed
(LIGHT) ON
The display is always lit
(LIGHT) OFF
The display only lights up when the
controls are accessed and remains on for 5
seconds after the last operation performed
P32
(DISP.
DATA)
D
C
P32/A
(DISP.DESC.)
D
C
P32/A.1
(CH.TEMP.)
(Default)
D
x
selection
C
The indicator displays the output
temperature from the primary heat
exchanger
P32/A.2
(OUTSIDET.)
The indicator displays the current external
temperature (with external probe Optional)
P32/B
(LANGUAGE)
D
C
ITALIAN
(Default)
All descriptions are given in Italian
A1
(ALPHANUM)
All descriptions are given in Alphanumeric
mode
P33
(EMER-
GENCY)
D
C
OFF
(EMERG.)
D
x
selection
C
By activating this function in winter mode,
the room heating function can be activated
even if the Remote Control or TA are out
of order
ON
(EMERG.)
RESET
(RESET
ALL)
D
x
selection
C
By pressing button “D” the customisations
made are reset, restoring the values set in
the factory
Customisations menu M3 (PERS.MENU).
AThis menu
contains all operating options that can be customised. (The
first entry of the various options that appears within the para-
meter is that selected by default).