Calibrate I sensor (Current sensor)
This wizard helps with the task of current sensor configuration. If you have the datasheet of the
sensor, or have previously measured these values, you can enter directly on the OSD setup screen.
Otherwise, you will also need an ammeter or a clamp ammeter to measure current drawn.
Although calibration can be performed with less than the maximum current drawn, to minimize
the maximum calibration error, you should not use a too low intensity calibration value.
The setup procedure is as follows:
•
Stop engine, wait for a few seconds to allow stabilizes the filter, and press OK to adjust
sensor’s offset.
•
With the help of the clamp, obtain the maximum current that can flow by the motor, and enter it
in the "Max. I".
•
Once the clamp meter reading matches the information given in the application, click "OK" to
record the voltage reached.
•
Press "END" when finished.