page 137
11.3. The unit status and the LEDs
Function
TDM_CONTROL_STATUS_REPORT
Library
TDM.LIB
Function symbol
Purpose
The function activates or deactivates the automatic status report
of the tdm R 360.
Parameter
Function inputs
Function outputs, none
Description
The status report provides the application software with all
relevant unit information:
•
currently displayed picture
•
currently displayed message
•
keyboard status (which key has been pressed or released)
•
LED is set or not set
•
unit status (e.g. preset value entry active)
TDM_CONTROL_STATUS_REPORT activates the automatic
status report. Each change of the above points is transferred to
the controller.
The current status can be evaluated with
TDM_REPORT_STATUS and TDM_REPORT_KEYDATA.
The function has to be called only once for switching on or
switching off. The execution of the function can then be blocked
via the input ENABLE. It is, however, useful to call the functions
in certain intervals (e.g. every 500 ms) when
TDM_CONTROL_STATUS_REPORT is active. That way it is
prevented that the monitoring of the unit status does not work
e.g. after a failure of the tdm power supply.
Name
Data type
Description
ENABLE
BOOL
TRUE:
function is executed
FALSE: function is not executed
ON
BOOL
TRUE:
automatic status report is
switched on
FALSE: automatic status report is
switched off
Summary of Contents for ecomat 100 R 360 Series
Page 1: ...System manual ecomat 100 type R 360 ...
Page 14: ...page 14 ...
Page 26: ...page 26 ...
Page 86: ...page 86 ...
Page 100: ...page 100 ...
Page 126: ...page 126 ...
Page 146: ...page 146 ...
Page 162: ...page 162 ...
Page 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Page 164: ...page 164 Annex 2 2 Type CR0016 ...
Page 165: ...page 165 Annex 2 3 Type CR0017 ...
Page 166: ...page 166 Annex 2 4 Type CR0501 ...