Function
SLAVE_8_CONFIG
Library
CRxxxx.LIB
Function symbol
Purpose
Sets parameters for or reads the configuration of an I/O module.
Parameters
Function inputs
Name
Data type
Description
NODE_ID
BYTE
Node number
CHANNEL_1
BYTE
Configuration parameter for channel 1
0 = OFF, 1 = binary input
CHANNEL_2
BYTE
Configuration parameter for channel 2
0 = OFF, 2 = binary output
3 = analog input, 4 = analog output
CHANNEL_3
BYTE
Configuration parameter for channel 3
0 = OFF, 1 = binary input
CHANNEL_4
BYTE
Configuration parameter for channel 4
0 = OFF, 2 = binary output
3 = analog input, 4 = analog output
CHANNEL_5
BYTE
Configuration parameter for channel 5
0 = OFF, 1 = binary input
CHANNEL_6
BYTE
Configuration parameter for channel 6
0 = OFF, 2 = binary output
3 = analog input, 4 = analog output
CHANNEL_7
BYTE
Configuration parameter for channel 7
0 = OFF, 1 = binary input
CHANNEL_8
BYTE
Configuration parameter for channel 8
0 = OFF, 2 = binary output
3 = analog input, 4 = analog output
PWM_FRQ
BYTE
PWM frequency in Hz (20 ... 200 Hz)
READ
BOOL
Read current module configuration
WRITE
BOOL
Write current module configuration
Summary of Contents for ecomat 100 R 360 Series
Page 1: ...System manual ecomat 100 type R 360 ...
Page 14: ...page 14 ...
Page 26: ...page 26 ...
Page 86: ...page 86 ...
Page 100: ...page 100 ...
Page 126: ...page 126 ...
Page 146: ...page 146 ...
Page 162: ...page 162 ...
Page 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Page 164: ...page 164 Annex 2 2 Type CR0016 ...
Page 165: ...page 165 Annex 2 3 Type CR0017 ...
Page 166: ...page 166 Annex 2 4 Type CR0501 ...