page 24
!"
The controller configuration screen is activated via the button
or via menu item
Window / PLC Configuration.
!"
The requested controller configuration (CR..._x.M66) is
called via menu item
Insert / Firmware
.
!"
The connection between controller and PC is established via
Online / Login.
The serial interface for establishing the
connection depends on the setting in
Extras / HW Config
(serial or CAN) and the subsequent parameterisation of the
PC interface under
Online / Communication Parameters..
.
It does not matter which project file is loaded (as long as
the project can be booted with routine PLC_PRG). The
translation processes started with the login can be
ignored. The system message:
Program has changed! Do you want to download the
new program?
can be answered with NO.
!"
Menu item
Extras / Load Hex file
in the screen
PLC
Configuration
deletes the current operating system in the
controller. The LED of the controller module flashes fast (5
Hz).
!"
Then reset the controller since the online connection
between PC and controller does no longer exist after the
operating system has been deleted.
!"
After the reset the new operating system can be loaded. The
process is the same as for "New controller".
The new controller configuration file now has to be used for all
application programs to be loaded in the controller from now on.
Summary of Contents for ecomat 100 R 360 Series
Page 1: ...System manual ecomat 100 type R 360 ...
Page 14: ...page 14 ...
Page 26: ...page 26 ...
Page 86: ...page 86 ...
Page 100: ...page 100 ...
Page 126: ...page 126 ...
Page 146: ...page 146 ...
Page 162: ...page 162 ...
Page 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Page 164: ...page 164 Annex 2 2 Type CR0016 ...
Page 165: ...page 165 Annex 2 3 Type CR0017 ...
Page 166: ...page 166 Annex 2 4 Type CR0501 ...