Electronic Preset Counter E89005
20
8.4 Pulse counter
8.4.1 Input
Submenues for the signal and control inputs�
Display
Description
Submenu
Value
InP.PoL
Input polarity
PnP
PNP: switching to Plus for all inputs in common
nPn
NPN: switching to 0 V for all inputs in common
FiLtEr
Filter for the signal inputs InpA and InpB
oFF
Maximum count frequency
on
Damped to approx� 30 Hz (for control with mechanical contacts)
Count
Count input mode
Cnt.Dir
Count/Direction
INP A: count input
INP B: count direction input
uP.dn
Differential counting [A-B]
INP A: count input add
INP B: count input sub
uP.uP
Totalising [A+B]
INP A: count input add
INP B: count input add
quAd
Quadrature input
INP A: count input 0°
INP B: count input 90°
quA2
Quadrature with pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A will be counted
quA4
Quadrature x4
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A and INP B will be counted�
A / B
Ratio measurement [A/B]
Inp A: count input A
Inp B: count input B
A % b
Percentage differential counting
[(A-B) / A in %]
Inp A: count input A
Inp B: count input B