Electronic Preset Counter E89005
48
Response time of the relay outputs
1-channel operation
< 100 ms @ 40 kHz
< 350 ms @ 65 kHz
2-channel operation
< 150 ms @ 40 kHz
< 600 ms @ 65 kHz
Frequencies (typical)
13 Frequencies (typical)
13.1 Pulse
counter
HTL level
AC supply
typ. Low
2,5 V
typ.
High
22
V
Add
Sub
Trail
AddAr
SubAr
AddBat
SubBat
TrailAr
AddTot
SubTot
Cnt.Dir
55 kHz
2,8 kHz
2,7 kHz
Up.Dn
Up.Up
29 kHz
2,8 kHz
2,7 kHz
Quad
Quad 2
28 kHz
1,4 kHz
1,3 kHz
Quad 4
18 kHz
1,2 kHz
0,9 kHz
A/B
(A-B)/A
29 kHz
13.2 Frequency
meter
HTL level
AC supply
typ. Low
2,5 V
typ.
High
22
V
HTL
5V
A
65 kHz
9 kHz
A B
A + B
A / B
(A-B)/A
65 kHz
9 kHz
Quad
30 kHz
9 kHz
NOTE: Switching levels of the input
Switching levels with AC supply:
HTL level
Low:
0 .. 4 VDC
High:
12 .. 30 VDC
en
gl
is
h
Seite 19
11.4 Timer
Seconds
0�001���999 999 s
Minutes
0�001���999 999 min
Hours
0�001���999 999 h
h�min�s
00h�00min�01s���99h�59min�59s
Min� time measurable
500 μs
Measuring error
< 50 ppm
Response time of the relay outputs
< 7 ms
11.5 Signal and Control inputs
Polarity
programmable NPN/PNP (for all inputs in common)
Input resistance
5 kΩ
Pulse shape
any
Switching level with AC supply
HTL level Low
0���4 V DC
HTL level High
12���30 V DC
Min� pulse length of the reset input
1 ms
Min� pulse length of the control inputs 10 ms
11.6 Outputs
11.6.1 Output 1
Type
relay with make contact, programmable as NC or NO
Switching voltage
max� 250 V AC / 110 V DC