Electronic Preset Counter E89005
22
Display
Description
Submenu
Value
AddbAt
Count mode ADDING with automatic reset and Batch counter
Output 2 (timed signal) active when main counter = preset value 2�
Automatic reset to zero when main counter = preset 2�
Batch counter counts the number of automatic repetitions of preset 2�
Output 1 active when Batch counter ≥ preset 1.
Manual reset sets both counters to zero�
Electrical reset only sets the main counter to zero�
SubbAt
Count mode SUBTRACTING with automatic reset and Batch counter
Output 2 (timed signal) active when main counter = zero�
Automatic reset to preset 2 when main counter = zero�
Batch counter counts the number of automatic repetitions of preset 2�
Output 1 active when Batch counter ≥ preset 1.
Manual reset sets main counter to preset value 2, batch counter to zero�
Electrical reset only sets the main counter to preset value 2�
Addtot
Count mode ADDING with automatic reset and Total counter
Output 2 (timed signal) active when main counter = preset value 2�
Automatic reset to zero when main counter = preset value 2�
Total counter counts all the count pulses from the main counter�
Output 1 active when total counter ≥ preset value 1.
Manual reset sets both counters to zero�
Electrical reset only sets the main counter to zero�
Subtot
Count mode SUBTRACTING with automatic reset and Total counter
Output 2 (timed signal) active when main counter = zero�
Automatic reset to preset value 2 when main counter = zero�
Total counter counts (sub from preset value 1) all count pulses from main
counter�
Output 1 active when Total counter ≤ zero.
Manual reset sets both counters to the preset values�
Electrical reset sets only main counter to preset value 2�
trAiL
Tracking Preset mode
When preset 2 is changed then preset 1 automatically tracks it�
Reset to zero�
Preset 1 relative to preset 2�
tr_Ar
Tracking Preset mode with automatic reset
When preset 2 is changed then preset 1 automatically tracks it�
Reset to zero�
Automatic reset to zero when main counter = preset value�
factory settings are highlighted in grey