UK
Electronic Preset Counter E89005
23
8.4.3 Config
Submenues for matching the input pulses and display�
Display
Description
Submenu
Value
FActor
Multiplication factor
01.0000
Factory setting
00.0001...
99.9999
Multiplication factor can be programmed from 00�0001 to 99�9999�
The setting 00�0000 will not beaccepted�
diViSo
Division factor
01.0000
Factory setting
01.0000...
99.9999
Division factor can be programmed from 01�0000 to 99�9999�
The setting < 01�0000 will not be accepted�
dp
Decimal point setting (only optical function)
0
no decimal place
0.0
1 decimal place
0.00
2 decimal places
0.000
3 decimal places
0.0000
4 decimal places
0.00000
5 decimal places
SetPt
Set value
000000
Factory setting
000000...
999999
Set value can be programmed from 000000 to 999999�
A previously programmed decimal point will be displayed�
CoLor
Display colour (not supported)
rEd
Upper line red�
Lower line red�
rEdGrn
Upper line red
Lower line green
factory settings are highlighted in grey