Electronic Preset Counter E89005
21
Display
Description
Submenu
Value
MPi
User input
LAtch
When the MPI input is activated the display is “frozen” and remains “frozen”
until the MPI input is deactivated�
Internally the preset counter continues counting�
tEAch
When the MPI input is activated the current count value for the preset that
has just been selected will be adopted as the new preset value�
SEt
When the MPI input is activated the preset counter will be set to the value
specified in the parameter SEtPt�
Loc.InP
Lock input
ProG
When the lock input is activated the programming is inhibited�
PrESET
When the lock input is activated the setting of the preset values is inhibited�
PrG.PrE
When the lock input is activated the setting of the preset values and the
programming are both inhibited�
factory settings are highlighted in grey
8.4.2 Mode
Submenues for output operations�
Display
Description
Submenu
Value
ModE
Submenu for determining the operation of the outputs
Add
Count mode ADD
Outputs active when count status ≥ preset value
Reset to zero�
Sub
Count mode SUBTRACT
Output 1 active when count status ≤ preset value 1.
Output 2 active when count status ≤ 0.
Reset to preset 2
AddAr
Count mode ADDING with automatic reset
Output 1 active when count status ≥ preset value 1.
Output 2 (timed signal) active when count status = preset value 2�
Automatic reset to zero when count status = preset value 2�
Reset to zero�
SubAr
Count mode SUBTRACTING with automatic reset
Output 1 active when count status ≤ preset value 1.
Output 2 (timed signal) active when count status = 0�
Automatic reset to preset 2 when count status = 0�
Reset to preset 2�