Electronic Preset Counter E89005
35
Display
Description
Submenu
Value
Loc.InP
Lock input
ProG
When the lock input is activated the programming is inhibited�
PrESET
When the lock input is activated the setting of the preset values is inhibited�
PrG.PrE
When the lock input is activated the setting of the preset values and the
programming are both inhibited�
factory settings are highlighted in grey
8.6.2 Config
Submenues for matching the input pulses and display�
Display
Description
Submenu
Value
FActor
Multiplication factor
01.0000
Factory setting
00.0001...
99.9999
Multiplication factor can be programmed from 00�0001 to 99�9999�
The setting 00�0000 will not beaccepted�
diViSo
Division factor
01.0000
Factory setting
01.0000...
99.9999
Division factor can be programmed from 01�0000 to 99�9999�
The setting < 01�0000 will not be accepted�
tModE
Display mode (time mode)
SEC -1
Calculation and display of the frequency or speed in 1/s�
Min -1
Calculation and display of the frequency or speed in 1/min�
dp
Decimal point setting (only optical function)�
0
no decimal place
0.0
1 decimal place
0.00
2 decimal places
0.000
3 decimal places
AVG
Moving average
oFF
Moving average off
AVG 2
Moving average on, calculated over 2 measurements�
AVG 5
Moving average on, calculated over 5 measurements�
AVG 10
Moving average on, calculated over 10 measurements�
AVG 20
Moving average on, calculated over 20 measurements�