Electronic Preset Counter E89005
50
11.11 Device safety
Design to
EN 61010 Part 1
Protection Class
2
Application area
Soiling Level 2
11.12 Mechanical Data
Housing
panel-mount housing to DIN 43 700, RAL 7021
Dimensions
48 x 48 x 91 mm
Panel cut-out
45
+0,6
x 45
+0,6
mm
Installation depth
ca� 107 mm incl� terminals
Weight
ca� 125 g
Protection
IP 65 (front)
Housing material
Polycarbonate UL94 V-2
Vibration resistance (EN 60068-2-6)
10���55 Hz / 1 mm / XYZ
30 min in each direction
Shock resistance (EN 60068-2-27)
100 g / XYZ
3 times in each directio
Cleaning
The front of the unit should only be cleaned using a soft damp
(water!) cloth�
11.13 Connections
Supply voltage and relay outputs
Plug-in screw terminal
7-pin, RM 5�08
Core cross section
max� 2�5 mm²
Signal and control inputs
Plug-in screw terminal
8-pin, RM 3�81
Core cross section
max� 1�5 mm²
12 Maintenance, repair and disposal
The unit is maintenance-free�
►
Do not open the housing as the device does not contain any components
which can be repaired by the user� The device must only be repaired by the
manufacturer�
►
Dispose of the device in accordance with the national environmental
regulations�