UK
Electronic Preset Counter E89005
49
Switching current
max� 3 A AC / DC
min� 30 mA DC
Switching capacity
max� 750 VA / 90 W
Mechanical switching cycles
2 x 10
7
N° of switching cycles
1 x 10
5
(at 3 A / 250 V AC)
N° of switching cycles
1 x 10
5
(at 3 A / 30 V DC)
11.6.2 Output 2
Type
relay with changeover contact
Switching voltage
max� 250 V AC/ 150 V DC
Switching current
max� 3 A AC / DC
min� 30 mA DC
Switching capacity
max� 750 VA / 90 W
Mechanical switching cycles
2 x 10
6
N° of switching cycles
5 x 10
4
(at 3 A / 250 V AC)
N° of switching cycles
5 x 10
4
(at 3 A / 30 V DC)
11.7 Supply voltage
Supply voltage
90���260 V AC, max� 8 VA
Frequency
50���60 Hz
Ext� fuse protection
T 0�1 A
11.8 Sensor supply
Sensor supply voltage
24 V DC, ± 15%
Current
80 mA
11.9 Climatic Conditions
Operating temperature
-20���65 °C
Storage temperature
-25���75 °C
Relative humidity
93 % at 40 °C, non-condensing
Altitude
to 2000 m
11.10 EMC
Noise immunity
EN 61000-6-2 with shielded signal and control cables
Noise emission
EN 55011 Class B