background image

GBA Global Bill Acceptors      

GBA ST1C Operation Manual

 

 

 

Page 1 of 30 

Astrosys International Ltd 

GBA ST1C Operations manual V1_4 

 
 
 

GBA ST1C 

Operation Manual 

 

 

 
 
 
 
 

This document is the copyright of Astrosys International Ltd. and may not be reproduced in total or in part 
by any means, electronic or otherwise, without the prior written consent of Astrosys International Ltd. 

 

Summary of Contents for ST1C

Page 1: ...national Ltd GBA ST1C Operations manual V1_4 GBA ST1C Operation Manual This document is the copyright of Astrosys International Ltd and may not be reproduced in total or in part by any means electroni...

Page 2: ...0 4 1 On board Push Button 10 4 2 PC Based GBA Tools 13 4 3 USB Mass Storage Device 13 4 4 Software Configuration Options 16 4 5 Illuminated Note Guide Patterns 17 5 0 ELECTRICAL INTERFACE SPECIFICATI...

Page 3: ...er range including Parking and Internet Kiosks The following features are also offered Up or Down entry stacking configuration Sense Technology bill discrimination Up to 32 different bills accepted wi...

Page 4: ...Bill Acceptance Rate Greater than 95 Cycle Time for Validation and Stack Typically less than 3 seconds Interface Protocols Supported Pulse Parallel ccTalk plain encrypted bi direction serial RS232 NA...

Page 5: ...he GBA ST1C product consists of Main Chassis 1 which supports the Top Sensor Assembly not shown and Bottom Sensor Assembly 2 Inter changeable accessories are 3 Bill Cassette 300 Bills storage 4 Facepl...

Page 6: ...dy The studs will locate into the joints To ensure that the cassette latch has successfully re engaged press down on the cassette lid Remove the cassette by sliding the cassette clip forwards away fro...

Page 7: ...m There is a different faceplate for each of the note guide widths and both styles of faceplate are available in either up or down stacking configuration 2 2 4 1 Up stacker Faceplate 2 2 4 2 Down stac...

Page 8: ...a sensor for detecting and reading the barcodes on a printed coupon The sensor uses green light so it can readily read thermally printed coupons The sensor can only scan one face of the coupon so the...

Page 9: ...required by the NAMA MDB specification This option must be specified when ordering the ST1C An adaptor cable is required to connect to a standard NAMA 6 pin connector Please contact Technical Support...

Page 10: ...ng press of more than 2 seconds will cancel the programming mode In the note enable and disable modes a sample note must then be inserted and scanned If the operation is successful the validator will...

Page 11: ...lack lines on the card 4 1 4 Configuration Procedure Re Calibration Although calibration of the GBA ST1C is not a necessity it is recommended periodically for preventative maintenance and also after a...

Page 12: ...nses Upper Right Green Red Green Red Upper Left Green Red Red Green Lower Right Green Red Red Red Lower Left Red Green Green Green Coupon Red Green Red Red Other sensors Optical Anti String Gate Red G...

Page 13: ...e Device The GBA ST1C validator can be supplied with an optional USB interface which can be used to reprogram a unit from a USB Mass Storage Device memory stick Those validators with a USB interface a...

Page 14: ...number is different from the current firmware whether higher or lower it will load that firmware and then restart Once it has restarted it will check the memory device for other files 4 If more than o...

Page 15: ...Download Disabled Orange Red Red Green Device Faults USB Device not recognised Orange Orange Red Green Cannot read MST Boot Sector Orange Orange Red Orange Error reading MST Orange Orange Red Red Fil...

Page 16: ...P 10 JVI VCCS Definitions of the above can be found in the Interface Description Manuals ccTalk Encryption Key Reset Should a validator require replacing in a ccTalk application the Encryption key wil...

Page 17: ...the interface selected the validator will give one of the following messages Interface Message to host Pulse and Parallel No message BSCP RS232 Note type zero stacked zero unknown denomination MDB Not...

Page 18: ...lector outputs Maximum Open Voltage 40V Maximum Sink Current 50mA 12VDC Maximum Output Low Voltage 0 4VDC Minimum Output High Voltage 2 4VDC Digital inputs Input low level voltage 0 1V Input high leve...

Page 19: ...T Mode Unlike standard Parallel Mode Parallel XT mode uses the BUSY line to signal the host when it is activated The ST1C can also be controlled using the ccTalk serial protocol although the implement...

Page 20: ...nternational Ltd GBA ST1C Operations manual V1_4 6 If a note is returned to the customer then the ST1C will wait up to 3 seconds for the user to remove it before powering down If the note has not been...

Page 21: ...4 Output n c n c n c 9 Whi Blk Grn n c n c n c RXD 10 Blue Inhibit Control Input Enable Inhibit Control Input Enable Inhibit Control Input Enable n c 11 Violet Vend 1 Output Confirm Signal To Start Se...

Page 22: ...en the acceptor is operating DATA Output used to send data to the host machine CTS Input from host that tells acceptor that host is ready to receive the message Enable Input Determines whether or not...

Page 23: ...2 3 Bottom Sensor Assembly 4 Pick off and discard any large items of debris from the note path of the Bottom Sensor Assembly Repeat for the other side of the note path on the drive belt assembly 5 Usi...

Page 24: ...is switched OFF 2 Remove the Cassette as described in section 2 2 1 Cassette Fitting Removal 3 Lift up the purple Access Latch on the back of the Bottom Sensor Assembly and gently slide the module out...

Page 25: ...ys personnel when assisting customers over the phone or by email The following functionality describes the operation of the LED Indication Status Standby Modes Solid Green Unit Operational Solid Orang...

Page 26: ...sh code is given when the note is removed the LED will flash red or orange a number of times Cause of Note Rejection Number of flashes Unrecognised note 1 Red Optical Anti String Gate was triggered 2...

Page 27: ...or no acceptance of one or more programmed notes 1 Note acceptance inhibited 2 Poor sensor readings 3 Insufficient power supply capacity 1 Note inhibit settings 2 Bottom Sensor Assembly fitting 3 Not...

Page 28: ...GBA Global Bill Acceptors GBA ST1C Operation Manual Page 28 of 30 Astrosys International Ltd GBA ST1C Operations manual V1_4 8 3 Dimensional Drawings 8 3 1 Upstacker...

Page 29: ...GBA Global Bill Acceptors GBA ST1C Operation Manual Page 29 of 30 Astrosys International Ltd GBA ST1C Operations manual V1_4 8 3 2 Downstacker...

Page 30: ...t liability for any errors contained within or omissions from this document Astrosys International Ltd shall not incur any penalties arising from the adherence to reliance on or interpretation of this...