8.5.3 Config
Submenues for matching the input pulses and display�
Display
Description
Submenu
Value
tModE
Unit of time
SEC
Unit of time: seconds
Decimal point setting determines the resolution�
Min
Unit of time: minutes
Decimal point setting determines the resolution�
hour
Unit of time: hours
Decimal point setting determines the resolution�
h.Min.S
Unit of time: Hrs� Min� Sec�
dp
Decimal point setting (only optical function)
0
no decimal place
0.0
1 decimal place
0.00
2 decimal places
0.000
3 decimal places
SetPt
Set value
000000
Factory setting
000000...
999999
Set value can be programmed from 000000 to 999999�
A previously programmed decimal point will be displayed�
CoLor
Display colour (not supported)
rEd
Upper line red�
Lower line red�
rEdGrn
Upper line red
Lower line green
factory settings are highlighted in grey
8.5.4 Reset mode
Submenues for reset mode�
Display
Description
Submenu
Value
rESmd
Setting the reset mode
Man.EL
Manual reset (with red key) and electrical reset (reset input)�
no rES
No reset possible (red key and reset input inhibited)�
EL.rEs
Only electrical reset possible (reset input)�
MAnrE
Only manual reset possible (red key)�
factory settings are highlighted in grey